Low Temperature Water Chiller

This low temperature water chiller provides cold water temperature rang from  35℃~35℃, and the cooling capacity is from 3KW~400KW. It is widely used in beverage filling, pharmaceutical, chemical, food and bioengineering, beer brewing and other industries.

Model: Low temperature water cooled

MOQ: 1pcs

Price terms: FOB Guangzhou

Warranty: 1 year

After sale service: Free training service

Industries: Beverage filling, pharmaceutical, chemical, food and bioengineering, beer brewing and other industries

Description

The low temperature water chiller consists mainly of:

Air Cooled Glycol Water Chiller

Water Cooled Glycol Water Chiller

Water Cooled Screw Type Glycol Chiller

Specification

CA-L Series Low temperature Air cooled industrial chiller
ModeCA-03LCA-05LCA-08(D)LCA-10(D)LCA-12(D)LCA-15LCA-20(D)LCA-25(D)LCA-30(D)LCA-40FL
Item
Nominal cooling capacity-5℃KW5.578.513.681720.422.63236.445.264
50HZ6.9910.4116.620.8224.9627.538.8455577.6
-10℃60HZ4.326.3810.812.7615.3220.226.531.3640.453
 5.227.7512.815.518.7224.3631.7634.448.7263.52
-20℃ 2.84.036.88.069.7612.817.3620.5425.634.72
 3.474.828.29.6411.815.4420.323.7630.8840.6
Total input powerKW3.34.687.259.911.3613.4719.2621.330.2438.7
Power supply voltage3PH 380V  50HZ(60HZ)
RefrigerantTypeR22(R404A/R507)
Control modeExpansion valve
CompressorTypeHermetic Scroll type(reciprocating type)
Power(KW)2.563.753.02*23.75*24.46*212.27.6*28.77*212.2*27.6*4
CondenserTypeHigh efficient finned copper tube+ low noise outer rotor fan
EvaporatorTypeShell and tube
Chilled fluid flow(m3/h)1.362.223.524.445.037.18.8410.0613.617.75
1.592.654.25.35.938.3710.4111.8616.3321.29
Inlet/outlet pipe caliber1″1″1″1-1/2″1-1/2″2″2-1/2″2-1/2″2-1/2″3″
Water pumpPower(KW)0.550.550.751.51.51.52.22.244
Pump head (m)20202020202020202520
Safety ProtectionCompressor overheating , over current, high and low pressure, over temperature , flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing.
DimensionL (mm)930114013101680168018502000200018501950
W (mm)5205607208108109901130113014801800
H (mm)1075114014301540154016801720186419001870
WeightKg1351602703203805206006609201400

Note

1. Nominal cooling capacity calculated according to: When at -10℃, inlet/ outlet chilled fluid temperature is 0℃/-5℃ ; when at -10℃, it is -5℃/-10℃; when at -20℃, it is -15℃/-20℃. Inlet/ outlet cooling air temperature: 30℃/38℃ 

2. Working condition: 

The temperature range of chilled fluid is from -25℃ to 10℃ Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃, It is better to run the chiller while the ambient temperature at or below 35℃, We reserve the right to modify the above information without further notice.

CW-L Series low temperature Water cooled industrial chiller
ModeCW-03LCW-05LCW-08(D)LCW-10(D)LCW-12(D)LCW-15LCW-20(D)LCW-25(D)LCW-30(D)LCW-40FL
Item
Nominal cooling capacity-5℃KW6.069.1514.918.3222735.640.85471.2
50HZ7.6111.21822.4273344506688
-10℃60HZ4.93711.814172229.4324458.8
 68.514.21720.62735385470
-20℃ 3.14.57.6910.81417.5222835
 3.85.4910.812.21722.6273445.2
Total input powerKW2.84.56.758.610.112.7517.220.9526.534
Power supply voltage3PH 380V  50HZ(60HZ)
RefrigerantTypeR22(R404A/R507)
Control mode Expansion valve
CompressorTypeHermetic Scroll type(reciprocating type)
Power(KW)2.253.7567.5911.257.5*29.37*222.530
CondenserType Shell and tube
Cooling water volume(m3/h)2.13.55.26.767.910.713.915.821.126.7
2.54.26.17.49.311.716.318.625.229.7
Inlet/outlet pipe caliber1-1/2″1-1/2″1-1/2″1-1/2″1-1/2″2″2″2-1/2″3″3″
EvaporatorType Shell and tube
Chilled fluid flow(m3/h)1.582.584.15.25.858.2510.311.6915.6520.6
1.863.084.96.26.99.7312.1113.7918.6724.8
Inlet/outlet pipe caliber1″1″1″1-1/2″2″2″2-1/2″2-1/2″2-1/2″3″
Water pumpPower(KW)0.550.750.751.11.11.52.22.244
Pump head(m)18181820202020202520
Safety Protection Compressor overheating , over current, high and low pressure, over temperature , flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing.
DimensionL(mm)89089011701170117017001700170018802100
W(mm)5005007107107108108108109101100
H(mm)94094013101310131016201620162018201960
WeightKg1301502853353605506507009001200

Note

1. Nominal cooling capacity calculated according to: When at -10℃, inlet/ outlet chilled fluid temperature is -0℃/-5℃ ; when at -10℃, it is -5℃/-10℃; when at -20℃, it is -15℃/-20℃. Inlet/ outlet cooling water temperature: 25℃/30℃.

2. Working condition: The temperature range of chilled fluid is from -25℃ to 10℃ Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃ , The temperature range of cooling water from 18℃ to 35℃, temperature difference between inlet and outlet coolig water is from 3.5℃ to 10℃. We reserve the right to modify the above information without further notice.

Specification

Technical parameters for Low temperature water cooled screw chiller unit
  项目Item         型号 ModelCSW-40LCSW-50LCSW-60LCSW-75LCSW-85LCSW-100LCSW-120LCSW-140LCSW-170DLCSW-200DLCSW-240DL
Nominal cooling capacity-10℃kW74.797.2107.5129.5167.4193.6230.2273.6334.8387.2460.4
-20℃50.465.672.587.4112.9130.6155.3184.6225.8261.2310.6
-30℃31.641.245.554.870.98297.5115.9141.8164195
Power supply voltage 3φ 380V 50Hz
Total input powerkW35.945.450.859.476.488.3105.2124.3152.8176.6210.4
CompressorType  Semi-hermetic screw type
Mode RC2-140BRC2-180BRC2-200BRC2-230BRC2-300BRC2-340BRC2-410BRC2-470BRC2-300B×2RC2-340B×2RC2-410B×2
Powerkw35.945.450.859.476.488.3105.2124.376.4*288.3*2105.2*2
Refrigerant R22/R404a
  Thermostatic expansion valve
Starting mode Y-△
Capacity control 0-25-50-75-100
EvaporatorType  Shell and tube high efficient heat exchanger
Chilled fluid flowm3/h22.529.532.239.243.159.164.478.486.197.3118.8
Inlet/outlet pipe caliberInch3″3″3″4″4″4″5″5″5″5″5″
CondenserType  High efficient horizontal Shell and tube heat exchanger
Cooling water flowm3/h18.423.926.331.637.447.852.663.275100128.8
Inlet/outlet pipe caliberInch3″3″3″4″4″4″5″4″*24″*24″*24″*2
Safety protectionCompressor overheating, overloading, high and low pressure, over temperature , flow switch, phase sequence, phase missing, exhaust overheating, anti-freezing.
DimensionLmm24002600290029002900290029502950295035803580
Wmm9409409009009009001100110011001100875
Hmm15401750185018501850185018501850185019501950
WeightN.Wkg820950112012001300192022502450250026103460
Running weightkg9701060127013801480223025502710275028603830
Note:1. nominal cooling capacity calculated according to: The chilled fluid is the 60% Ethylene Glycol aqueous solutions. Inlet/ outlet cooling water temperature: 32℃/ 37℃.
2. Working condition: The temperature range of chilled fluid is from -5℃ to -30℃. Temperature difference between inlet and outlet chilled fluid is from 2.5℃ to 10℃
The temperature range of cooling water from 22℃ to 37℃, Temperature difference between inlet and outlet cooling water is from 3.5℃ to 10℃.
3. The 60% Ethylene Glycolshould be prepared in customer side. We reserve the right to modify the above information without further notice.
 

Get in touch with us